Optical Information Guide (OIG)
Selected: Digital Imaging

Designs For Vision New Zealand
PO Box 38365 
Howick
Auckland 2014
Freephone: 0800 338 800
Contact: Ralph Thompson (Optometry diagnostic)
Email: ralpht@dfv.com.au
Mob: 021 990 200
Contact: Gian Victoria (Ophthalmology diagnostic)
Email: gian.victoria@dfv.com.au
Mob: 021 534 198
KEELER
• Symphony Slit lamps with Digital Imaging Camera plus Software
• Video Vantage Digital Wireless BIO with Capture Software
iCare
• DRS Plus Retinal Imager (true colour confocal 45 degree image)
• Eidon Retinal Imager (true colour confocal 60 degree image and auto mosaic)
• Eidon AF Retinal Imager (true colour confocal 60 degree image, auto mosaic & Autofluorescence)
• Eidon FA Retinal Imager (true colour confocal 60 degree image, auto mosaic, Autofluorescence & Fluorescein angiography)
• Compass retinal image & perimeter (true colour confocal 60 degree)
• Maia Microperimeter with line scanning ophthalmoscope (36 degree image)
• S-Maia Scotopic Microperimeter with line scanning ophthalmoscope (36 degree image)
Natus
• Retcam Widefield Digital Fundus Camera for paediatric examinations
Oculus
• Keratograph 5M: corneal topography/anterior segment imaging/dry eye diagnostic
• Oculus ImageCam 3: slit lamp documentation
Rodenstock
• Slit Lamps
• Rodacam Slit Lamp imaging
Volk
• Volk Pictor Hand Held Non Myd Fundus Camera

Device Technologies NZ Ltd
47 Arrenway Drive
PO Box 302 413
Albany
Auckland 0751
Freephone: 0508 338 423
Web: www.device.co.nz/ophthalmology
Orders: customers@device.co.nz
Sales enquiries: dsonderegger@device.co.nz
Contact: Diego Sonderegger
Anterior Segment Analysers
Ziemer
• Galilei G6 and G4 Dual Scheimpflug Imaging combined with placido topography
Biometer (Combined with Anterior Segment Analyser)
Ziemer
• Galilei G6 – Dual Scheimpflug Imaging combined with placido topography and biometry
B Scan Ultrasound
Quantel Medical
• Diagnostic ocular A & B Scan Ultrasound systems, Including 50MHz high definition UBM
Digital Fundus cameras
Topcon
• TRC-NW400 – Autoaligning non-mydriatic retinal camera
• OCT-1 Maestro2 – Autoaligning non-mydriatic retinal camera with pinpoint recognition Spectral domain OCT (50KHz)
• TRC-50DX – Mydriatic colour, red-free and FA retinal camera Optional ICG and auto fluorescence function (tilts and sviwels)
Digital Slit Lamp camera
Topcon
• DC-4 – High quality Digital Slit Lamp imaging system with IR for Meibomian gland viewing (FAG option with exciter and barrier filter)
OCT
Topcon
Triton
• Swept Source OCT with integrated non-mydriatic fundus camera, Glaucoma suite
Triton plus
• With additional FA and FAF
• OCT-A (OCT-Angiography) option
• 16mm wtw Anterior segment option
Maestro2 3D OCT-1
• With integrated fundus Camera & Anterior segment, Glaucoma suite
Software
Topcon
Harmony
Brand “agnostic” Ophthalmic image data management System (Multi-site capable)
Integrates images and reports from over 180 ophthalmic devices for viewing, manipulation, storage, archiving and patient information retrieval Diabetic retinopathy reporting
• IMAGEnet 6 – Image-manipulation, -storage, -archiving and information retrieval
• Fastmap – 3D OCT scan-manipulation, -storage, -archiving and information retrieval
Perimeters
Frey
• AP-250 – Static Perimetry
• AP-250BY – Static Perimetry, blue/yellow
• AP-300 – Kinetic & Static Perimetry, white/white, blue/yellow
Vision charts
Topcon
• PC-50 – 19”LCD chart compatible with CV-5000
Frey
• CP-400 – 24” LCD chart
• CP-600P – 24” LCD chart

Ophthalmic Instrument Company (O.I.C)
PO Box 36475
Northcote
Auckland 0748
Unit 12, 77 Porana Road
Hillcrest
Auckland 0627
Tel: 09 443 0072
Fax: 09 443 0225
Freefax: 0508 20 20 20
Email: tim@oic.co.nz
Web: www.oic.co.nz
Contact: Tim Way
• Kowa Nonmyd WX 3D Stereo Disc Camera
• Kowa VK2 digital imaging software
• Medmont DV-2000 digital imaging for slit lamps and retinal cameras, etc
• Nidek 3D analysing system
• CSO elite digital slit lamp with camera
• Nidek AFC-330 Auto tracking Non-mydriatic fundus camera
• Heidleberg Engineering Spectralis Fluorescein & ICG Angiography/OCT System

Optos Australia
10 Myer Court
Beverley SA 5009
Australia
Tel: +61 8 8444 6500
Fax: +61 8 8444 6555
Email: auinfo@optos.com
Web: www.optos.com
Ultra-Widefield Retinal Imaging Devices
Optos’ ultra-widefield imaging devices provide the ONLY 200° single non-contact retinal image. optomap® imaging takes less than half a second to help prevent vision loss and provide enhanced clinical information which facilitates in the early detection, management and treatment of disorders and diseases evidenced in the retina. Optos’ ultra-widefield technology can also image pathology past the vortex vessels, helping you find disease sooner and treat it more effectively.
Please refer to the Optos website for a full range of products

ZEISS
PO Box 121001 
Auckland 0650
22 Fremlin Place
Avondale
Auckland 1026
Free phone: 0800 334 353
Fax: +64 9 837 5619
Web: www.zeiss.co.nz
Contact: ZEISS Auckland Office
Email: med.au@zeiss.com
Tel: 0800 334 353
Optical Coherance Tomography
• CIRRUS HD-OCT 6000
• CIRRUS HD-OCT 500/5000
• PLEX Elite 9000
Fundus Cameras
• CLARUS 500 true colour ultra-widefield retinal camera
• CLARUS 700 true colour ultra-widefield retinal camera with flourescein angiography
• VISUSCOUT 100 hand held fundus camera
Software
• FORUM Eye Care Data Management with Glaucoma Workplace, Retina Workplace and EQ Workplace
• Review Software (CIRRUS HD-OCT, CLARUS and ATLAS Corneal Topographer)


